![]() In the Phidget Control Panel, open the channel for your device and click on the icon next to the data type that you want to plot. Note: Graphing and logging is currently only supported in the Windows version of the Phidget Control Panel. A Hardware mounting kit (4 nuts and bolts (M3), 4 plastic spacers).See our tutorial on Addressing EMI Issues. Very long thermocouples are okay (even 100m), but if there is measurement stability issues or USB resets, ferrite beads can be added to the thermocouple wire close to the Phidget Temperature Sensor. It is possible to interface other thermocouple types by converting the measured potential returned by the Temperature Sensor into Celsius using the appropriate tables the formula and links to the tables are described in the 1048 User Guide. J, K, E and T thermocouples are directly supported in the library and return the measured temperature in ☌. Thermocouples are widely used to measure extreme temperatures impossible to measure with other types of sensors. The 1048_1B is only compatible with our Phidget22 drivers, so if you're using Phidget21 you'll have to upgrade before using it. It comes in a plastic shell enclosure and you can now choose which cables you want to have included. Replaced by the 1048_1B - PhidgetEncoder HighSpeed 4-Input. ![]()